A water heater pilot light going out after adjusting the temperature control dial often indicates a faulty thermocouple. Another possible reason could be an issue with the gas valve.

A reliable water heater is essential for comfortable living, especially during colder months. Issues with the pilot light can disrupt your daily routine and cause frustration. Several factors can cause the pilot light to go out, including a malfunctioning thermocouple or gas valve problems.

Understanding these common issues can help you troubleshoot and maintain your water heater more effectively. Regular maintenance and timely repairs can extend the lifespan of your unit, ensuring a steady supply of hot water. Read on to learn more about diagnosing and fixing pilot light issues in your water heater.

Common Causes

Water Heater Pilot Goes Out After Turning Temp Control Dial

The thermocouple is a safety device. It senses the pilot flame. If it is faulty, the gas will shut off. This will cause the pilot light to go out. Dirt or corrosion can also affect it. Regular cleaning can help.

The pilot tube carries gas to the pilot light. If it gets blocked, the pilot will not stay lit. Dirt, dust, or spider webs can cause blockages. Cleaning the tube can solve the problem. Regular checks can prevent future issues.

The gas control valve is essential. It controls gas flow to the pilot light. If it is faulty, the pilot light will go out. Replacing the valve may be necessary. A professional should handle this task. Safety is important.

Water Heater Pilot Goes Out After Turning Temp Control Dial

Credit: diy.stackexchange.com

Diagnosing The Problem

Water Heater Pilot Goes Out After Turning Temp Control Dial

Check if the pilot light is out. Look for loose connections or broken parts. Make sure the area is clean and free of debris.

Smell for gas around the heater. Use a soapy water solution to find bubbles. Bubbles mean there is a gas leak. Turn off the gas and call a professional.

The thermocouple is a safety device. It tells the gas valve to open or close. Use a multimeter to test it. If it reads below 20 millivolts, replace it.

Tools Needed

Water Heater Pilot Goes Out After Turning Temp Control Dial

A wrench set helps to loosen and tighten nuts and bolts. Make sure you have different sizes. Always use the correct size to avoid damage.

A multimeter checks for electrical issues. It measures voltage, current, and resistance. Ensure the water heater is off before using it.

A cleaning brush removes dirt and debris. Clean the pilot light area regularly. This helps maintain proper function.

Safety Precautions

Water Heater Pilot Goes Out After Turning Temp Control Dial

Always turn off the gas supply before working on your water heater. Locate the gas control valve and turn it to the “off” position. This will prevent any gas leaks. Ensure the area is safe before proceeding with any repairs.

Proper ventilation is crucial. Open windows and doors to allow fresh air to circulate. This will help to disperse any gas that may have leaked. Never work in a confined space without adequate ventilation.

Wear protective gloves and safety goggles. This will protect your hands and eyes from any potential hazards. Ensure you have a fire extinguisher nearby. Safety should always be your top priority.

Step-by-step Repair Guide

Water Heater Pilot Goes Out After Turning Temp Control Dial

Turn off the gas supply and let the heater cool. Remove the cover panel to access the pilot tube. Use a small brush to clean the tube. Blow air through it to remove debris. Reassemble the parts and turn the gas supply back on. Light the pilot and check for a steady flame.

Turn off the gas and disconnect the thermocouple from the gas control valve. Remove the old thermocouple from its bracket. Install the new thermocouple in the same position. Reconnect it to the gas control valve. Turn on the gas and light the pilot.

Turn off the gas supply before adjusting the valve. Locate the adjustment screw on the valve. Turn the screw clockwise to increase the gas flow. Turn it counterclockwise to decrease the flow. Light the pilot and observe the flame. Adjust until the flame is steady and blue.

Water Heater Pilot Goes Out After Turning Temp Control Dial

Credit: www.reddit.com

When To Call A Professional

Water Heater Pilot Goes Out After Turning Temp Control Dial

Some problems need a professional’s help. If the pilot light goes out often, it could be a complex issue. A professional can find and fix the problem quickly. They have special tools and know-how.

If the pilot light keeps going out, call an expert. A repeated issue may be dangerous. Professionals can check for hidden problems. They make sure your water heater works safely.

A gas line issue is serious. If you smell gas, call a professional right away. They can fix gas leaks safely. Never try to fix a gas line yourself. Professionals have the right skills and tools.

Preventative Maintenance Tips

Water Heater Pilot Goes Out After Turning Temp Control Dial

Check your water heater regularly. Look for any signs of wear or damage. Fix small issues before they become big problems. This helps keep the water heater working well.

Keep the water heater clean. Remove dust and debris from the unit. Clean the burner and pilot light area. A clean heater runs more efficiently and safely.

Hire a professional for an annual check-up. Experts can spot problems early. They also ensure all parts are in good condition. Regular servicing extends the life of your water heater.

Choosing A New Water Heater

Water Heater Pilot Goes Out After Turning Temp Control Dial

Energy-efficient water heaters save money. They also help the environment. Look for the Energy Star label. This label means the heater uses less energy. Solar water heaters are very efficient. They use the sun’s power. Tankless water heaters only heat water when needed. This saves energy too.

Think about the size of your family. A larger family needs more hot water. A small family might need a smaller tank. Water heaters come in different sizes. Choose the right size for your needs. A 40-gallon tank is good for a family of four. A 20-gallon tank is good for one or two people.

Brand Features
Rheem Energy-efficient, durable, various sizes
AO Smith Long-lasting, high-performance, good warranty
Bradford White Reliable, efficient, made in the USA
Water Heater Pilot Goes Out After Turning Temp Control Dial

Credit: www.supertechhvac.com

Frequently Asked Questions

Why Does The Pilot Light Go Out When I Turn The Heater On?

A faulty thermocouple often causes the pilot light to go out when you turn the heater on. It may also be due to a clogged pilot tube or gas valve issues. Inspect and clean these components or consult a professional for repair.

Why Does My Pilot Light Keep Going Out On My Hot Water System?

Your pilot light may keep going out due to a faulty thermocouple, dirty pilot tube, or gas supply issues.

Why Wont My Pilot Light Stay Lit When I Release The Knob?

Your pilot light won’t stay lit because of a faulty thermocouple, dirty pilot tube, or insufficient gas pressure. Check and replace these parts if needed.

Why Does My Gas Water Heater Pilot Light Go Out When I Release The Button?

The thermocouple might be faulty or misaligned. It fails to signal the gas valve to stay open. Dirt or debris could also be blocking the pilot tube. Ensure the pilot flame is strong and blue. Cleaning or replacing the thermocouple often solves the issue.

Conclusion

Troubleshooting a water heater pilot light can be simple with the right steps. Always prioritize safety and follow manufacturer guidelines. Regular maintenance helps prevent future issues. If problems persist, contact a professional for assistance. Keeping your water heater in top shape ensures consistent hot water supply.

Stay proactive to avoid inconvenient breakdowns.

Rate this post

Leave a Reply

Your email address will not be published. Required fields are marked *